ULTRA NT SCIF Barrier-PERF | 65.55 dB MSE 100 MHz–10 GHz - 500 sq/ft
**ULTRA NT SCIF Barrier - PERFORATED** with a minimum shielding effectiveness of 65.55 dB. This performance has been tested across frequencies from 100 MHz to 10 GHz, following the IEEE-299 testing guidelines, and it is fully compliant with Sensitive Compartmented Information Facilities (SCIF) application guidelines. The barrier provides effective RF attenuation against a wide range of RF frequencies. Additionally, all our products are manufactured in the United States
Our prices include free UPS ground delivery! Plus, ALL orders ship out with tracking information provided the following business day!
**PRODUCT SPECIFICATIONS**
1. Shielding Effectiveness tested between the frequencies of 100 MHz to 10 GHz equals a minimum shielding effectiveness of 65.55 dB, following IEEE-299-2006 testing standards
3. Roll Size: 48 inches wide x 125 feet long (500 square feet per roll)
4. Manufactured in: United States
5. Material: Two-sided reflective aluminum foil with polyethylene woven reinforcement with a combined 6.52 mil thickness.
6. Emissivity: ASTM C1371-04A = 0.03
7. Reflectivity: Reflects 97% of radiant heat
8. Corrosiveness: Passes ASTM D3310-00
9. Fire Rating: Class 1, Class A (ASTM E84-10)
10. Flame Spread and Smoke Development: Flame spread = 0, Smoke development
11. Bleeding and Delamination: No bleeding or delamination (ASTM C1224-03)
12. Pliability: No cracking (ASTM C1224-03)
13. Water Vapor Permeability: 2.69 Perm rating (ASTM E96-05)
14. Resistance to Fungi: No growth (ASTM C1338-08)
15. Tensile Strength and Tear Resistance (Length): 101.47 pounds of force
16. Tensile Strength and Tear Resistance (Width): 86.22 pounds of force
17. Product thickness equals 6.52 mils
**CONSUMER ALERT: ** This product is exclusively available through National Building Supplies, LLC, and on our authorized product website, www.ultrantscifbarrier.com. It cannot be purchased through Eco Foil, Covertech, or any other website, including Amazon.
**PRODUCT TESTING** We have provided our comprehensive product testing report in our submittal and testing sheet below to support our performance claims. The testing was conducted at MET Laboratories, Inc., located at 914 West Patapsco Avenue in Baltimore, Maryland. We assure you that all the equipment used for testing is accurate and has recent traceability to the National Institute of Standards and Technology. The testing process adhered to the guidelines outlined in IEEE-299
CLICK HERE- To download the ULTRA NT SCIF Barrier - PERFORATED product testing
CLICK HERE- To request a quote and receive the MAXIMUM DISCOUNT!
Our goal is to complete all quote requests within an hour or less during regular business hours (Monday -Friday from 8 am to 5 pm CST).